    WANG Yan-jiang, XIE Xi-sheng, FENG Sheng-gang. Influence of urokinase continuous micro-pump on the malfunction of tunneled cuffed catheters in the hemodialysis patients[J]. Journal of Clinical Nephrology, 2018, 18(2): 103-106. DOI: 10.3969/j.issn.1671-2390.2018.02.008
    Citation: WANG Yan-jiang, XIE Xi-sheng, FENG Sheng-gang. Influence of urokinase continuous micro-pump on the malfunction of tunneled cuffed catheters in the hemodialysis patients[J]. Journal of Clinical Nephrology, 2018, 18(2): 103-106. DOI: 10.3969/j.issn.1671-2390.2018.02.008

    尿激酶持续微量泵入对透析患者带隧道带涤纶套导管功能不良的影响

    Influence of urokinase continuous micro-pump on the malfunction of tunneled cuffed catheters in the hemodialysis patients

    • 摘要: 目的 探讨尿激酶持续微量泵入对血液透析患者带隧道带涤纶套导管(TCC)功能不良的影响。方法 选取南充市中心医院血液透析室维持性血液透析并伴TCC功能不良患者30例,随机分为观察组(n=10),尿激酶传统封管组(n=10)和尿激酶持续微量泵入组(n=10)。观察并比较各组患者透析时的血流速度、透析充分性、一个月内TCC功能不良的发生频数以及并发症的发生情况。结果 与观察组相比,尿激酶传统封管组及尿激酶持续微量泵入组患者的透析血流速度显著增加,透析充分性更高,一个月内发生导管功能不良的频数更低,差异具有统计学意义(P<0.05);与尿激酶传统封管组相比,尿激酶持续微量泵入组患者在透析时血流速度,透析充分性方面显著提升,1个月内TCC发生功能不良的频数显著降低(P<0.05)。各组患者均无出血并发症的发生。结论 尿激酶持续微量泵入可显著改善尿毒症患者TCC功能不良状况,疗效显著,值得临床推广应用。

       

      Abstract: Objective To explore the influence of urokinase continuous micro-pump on the malfunction of tunneled cuffed catheters in the hemodialysis patients.Methods Thirty maintenance hemodialysis patients with the malfunction of tunneled cuffed catheters were chosen from the Hemodialysis Room of Nanchong Central Hospital. Patients were randomly divided into observation group (n=10), urokinase traditional sealed tube group (n=10) and urokinase continuous micro-pump into group (n=10). Blood flow velocity, dialysis adequacy and the occurrence of adverse catheter function within one month and complications were observed and compared among the groups.Results As compared with the observation group, the blood flow velocity of the dialysis and the dialysis adequacy in the urokinase traditional sealed tube group and the rokinase continuous micro-pump into group were significantly higher, and the occurrence frequency of adverse catheter function within one month was lower(P<0.05). Compared with the urokinase traditional sealed tube group, the blood flow velocity of the dialysis and the dialysis adequacy of the rokinase continuous micro-pump into group were higher, and the occurrence of adverse catheter function within one month was significantly lower (P<0.05). No bleeding complications occurred in all patients.Conclusions The dysfunction of the tunneled cuffed catheters can be significantly improved by the continuous micro pump of the urokinase. The effect of the continuous micro pump of the urokinase was significant, which was worthy of clinical application.

       

    /